Angkop Corp — Technical Reference

Fire Performance
& Compliance

ASTM E84 Class A classification — mapped to IBC and NFPA 101 occupancy requirements for AEC specifiers evaluating Flexible Natural Stone™ for interior and exterior applications.

01

Material & Standard

Material

Flexible Natural Stone™ (Eco-Flexi MCM)

Standard

ASTM E84 — Surface Burning Characteristics of Building Materials

Classification

Class A

Flame Spread Index

≤ 25

Smoke Developed Index

≤ 450

EU Equivalent

Class A Compliant

02

ASTM E84 — Test Method Overview

ASTM E84 evaluates two surface burning characteristics when a material is exposed to a defined flame source over a 10-minute period in a Steiner tunnel furnace apparatus. Results are expressed as two independent indices.

Flame Spread Index (FSI)
Rate at which flame travels across the material surface. Benchmarked against red oak (FSI = 100) and inorganic reinforced cement board (FSI = 0). Lower values indicate slower flame propagation.
Smoke Developed Index (SDI)
Cumulative optical density of smoke generated during the test period. Evaluated independently from FSI. Both indices must satisfy the class threshold for classification.
Class Flame Spread Index Smoke Developed Index Typical Application
A — Flexible Natural Stone™ 0 – 25 0 – 450 Exits, corridors, high-rise, health care
B 26 – 75 0 – 450 General commercial interiors
C 76 – 200 0 – 450 Residential, low-occupancy spaces

03

IBC and NFPA 101 — Where Class A Is Required

The following maps Class A requirements to occupancy types and space conditions under the International Building Code (IBC) and NFPA 101 Life Safety Code. Specifiers must verify the edition adopted by the authority having jurisdiction (AHJ) and any local amendments in force at the project location.

IBC Section 803 — Interior Wall and Ceiling Finish

Occupancy / Space IBC Reference Required Class
Egress corridors — all occupancy groups IBC 803.13 Class A
Vertical exit enclosures (stairwells, exit passageways) IBC 1023.6 Class A
Assembly occupancies (Groups A-1 through A-5) IBC 803, Table 803.13 Class A
High-rise buildings IBC Section 403 Class A — all interior finish surfaces
Institutional occupancies (Group I) — patient rooms, corridors IBC Table 803.13 Class A
Mercantile and Business (Groups M, B) — corridors and lobbies IBC Table 803.13 Class A or B

NFPA 101 — Life Safety Code, Table 10.2.3.4

Occupancy / Space Required Class
Exits and exit access corridors — health care, detention, high-rise Class A
Lobbies and common areas — assembly and educational occupancies Class A
Spaces with high occupant load or constrained egress paths Class A

04

Where Flexible Natural Stone™ Applies

Space Type Typical Code Requirement Flexible Natural Stone™
Egress corridors Class A (IBC 803.13) Compliant
Exit stairwells Class A (IBC 1023.6) Compliant
Hotel lobbies & corridors Class A or B (AHJ-dependent) Compliant
Commercial office interiors Class A or B Compliant
Retail interiors (Group M) Class A or B Compliant
Multifamily common areas Class A or B Compliant
Health care corridors (Group I-2) Class A Compliant
Exterior cladding (all-weather rated) Refer to IBC Chapter 14 Verify with AHJ

05

Fire-Rated Assembly — Specifier Notes

Flexible Natural Stone™ is a surface finish material. It does not constitute a fire-rated assembly independently and must not be specified as a substitute for a rated wall, floor, or ceiling assembly.

The underlying wall assembly — substrate, framing, insulation — must independently satisfy any required fire-resistance rating (1-hour, 2-hour, etc.) per IBC Chapter 7 or applicable UL assembly listings. The finish material is applied over a compliant assembly, not in place of one.

Adhesive selection should be reviewed for compatibility with the fire-rated assembly. Consult the structural engineer of record (SER) or fire protection engineer (FPE) where required by the project scope or AHJ.

Penetrations through fire-rated assemblies must be firestopped per IBC Section 714, independent of the finish material applied to the assembly face.

06

Available for Specification Packages

The following documents are available upon request for inclusion in project specification packages, permit submissions, and AHJ review. Contact project@angkop.ca with project name and jurisdiction.

  • ASTM E84 Test ReportPDF — Available upon request
  • Material Safety Data Sheet (SDS)PDF — Available upon request
  • Product Technical Data SheetPDF — Available upon request
  • Installation GuidePDF — Available upon request
  • EU Class A Compliance CertificatePDF — Available upon request

Specification Support

Request documentation for your project.

project@angkop.ca · +1 (778) 909-9524

This page is maintained as a technical reference for AEC professionals. Content reflects general code provisions and does not constitute legal or engineering advice. Specifiers are responsible for verifying compliance with the applicable edition of adopted codes and local amendments in force at the project jurisdiction.